Controle Endometrial e Eficácia dos Dispositivos Intrauterinos: Revisão das Vantagens e Limitações dos DIU-LNG

Autores

  • Júlia Valena Paiva da Fonseca Universidade Nove de Julho (UNINOVE)
  • Carla Katharina Torres Begot da Rocha Universidade Federal do Pará (UFPA)
  • Giulia Fonsceca Faculdade da Saúde e Ecologia Humana (FASEH)
  • Mariana Bressan Pizarro Faculdade de Medicina de Itajubá (FMIT)
  • Luana Lugli Facaculda Estácio de Sá (UNESA)
  • Caroline Topassi Universidade Estácio de Sá (UNESA)
  • Maria Laura Brum Paes Universidade Estácio de Sá (UNESA)
  • Iara Moura Rocha Universidade de Pernambuco (UPE)
  • Breno Clarkes Pereira Gonçalves Pontifícia Universidade Católica de Minas Gerais (PUCMG)
  • Julia Heiko Filgueira Otino Faculdade de Medicina do ABC (FMABC)
  • Lorena Doretto Oliveira Universidade de Marília (UNIMAR)
  • Celito Francisco Sari Junior Centro Universitário de Valença (UNIFAA)

DOI:

https://doi.org/10.36557/2674-8169.2024v6n6p2143-2153

Palavras-chave:

Dispositivos Intrauterinos; Controle Endometrial;Sangramento Menstrual.

Resumo

Este estudo avaliou a eficácia dos dispositivos intrauterinos (DIUs) no controle endometrial, explorando os mecanismos subjacentes aos benefícios clínicos e investigando vantagens e limitações dos diferentes tipos de DIUs. A revisão integrativa foi meticulosamente planejada para assegurar uma avaliação abrangente dos efeitos dos DIUs no controle endometrial, com foco nas alterações celulares e condições endometriais. Os estudos revisados destacam a eficácia dos dispositivos intrauterinos de liberação de levonorgestrel (DIU-LNG) na redução do volume menstrual, resultando em taxas superiores de continuação para fins contraceptivos. No entanto, desafios como o sangramento irregular requerem intervenções adicionais. O aconselhamento intensivo é crucial para estratégias personalizadas que atendam às necessidades individuais das pacientes. Fatores anatômicos, como o tamanho da cavidade uterina, influenciam os resultados clínicos, especialmente para usuárias de DIU-LNG. O perfil clínico das pacientes desempenha um papel importante no manejo do DIU-LNG, particularmente no tratamento de sangramento uterino anormal (SUA). As conclusões enfatizam a complexidade do uso de DIUs e a necessidade de uma abordagem abrangente e personalizada para otimizar sua eficácia e aceitação clínica.

Downloads

Não há dados estatísticos.

Referências

Al Shukri, M. et al. Is there a difference in the clinical profile and outcome of women using levonorgestrel IUD for abnormal uterine bleeding and those using it for contraception?: A comparative cross-sectional study. Turkish Journal of Obstetrics and Gynecology, 21(1): 7-14, 2024.

Costescu, D. et al. Discontinuation rates of intrauterine contraception due to unfavorable bleeding: a systematic review. BMC Women's Health, 22(1): 82, 2022.

Heikinheimo, O., et al. Bleeding pattern and user satisfaction in second consecutive levonorgestrel-releasing intrauterine system users: results of a prospective 5-year study. Human Reproduction, 29(6): 182-1188, 2014.

Kaislasuo, J., et al. Menstrual characteristics and ultrasonographic uterine cavity measurements predict bleeding and pain in nulligravid women using intrauterine contraception. Human Reproduction, 30(7): 1580-1588, 2015.

Luukkainen, T., & Toivonen, J. Levonorgestrel-releasing IUD as a method of contraception with therapeutic properties. Contraception, 52(5): 269-276, 1995.

Minalt, N. et al. Association between intrauterine device use and endometrial, cervical, and ovarian cancer: an expert review. American Journal of Obstetrics and Gynecology, 229(2): 93-100, 2023.

Miranda, L. et al. Continuation Rates of the 52-mg Levonorgestrel-releasing Intrauterine System according to the Primary Reason for its Use. Revista Brasileira de Ginecologia e Obstetrícia, 43(4): 291-296, 2021.

Modesto, W. et al. A randomized clinical trial of the effect of intensive versus non-intensive counselling on discontinuation rates due to bleeding disturbances of three long-acting reversible contraceptives. Human Reproduction, 29(7), 2014.

Papaikonomou, K. et al. Mifepristone treatment prior to insertion of a levonorgestrel releasing intrauterine system for improved bleeding control - a randomized controlled trial. Human Reproduction, 33(11): 2002-2009, 2018.

Al Shukri, M. et al. Is there a difference in the clinical profile and outcome of women using levonorgestrel IUD for abnormal uterine bleeding and those using it for contraception?: A comparative cross-sectional study. Turkish Journal of Obstetrics and Gynecology, 21(1): 7-14, 2024.

Downloads

Publicado

2024-06-29

Como Citar

Valena Paiva da Fonseca, J., Torres Begot da Rocha, C. K., Fonsceca, G., Bressan Pizarro, M., Lugli, L., Topassi, C., … Sari Junior, C. F. (2024). Controle Endometrial e Eficácia dos Dispositivos Intrauterinos: Revisão das Vantagens e Limitações dos DIU-LNG. Brazilian Journal of Implantology and Health Sciences , 6(6), 2143–2153. https://doi.org/10.36557/2674-8169.2024v6n6p2143-2153