Current literature review on methods for measuring the stability of osseointegrable implants.
PDF (English)

Palavras-chave

Estabilidade do implante primário, análise de frequência de ressonância, estabilidade do implante secundário.

Como Citar

Santos Araújo , A., & Santos Araújo , M. . (2020). Current literature review on methods for measuring the stability of osseointegrable implants . Brazilian Journal of Implantology and Health Sciences, 2(12), 45–59. https://doi.org/10.36557/2674-8169.2020v2n12p45-59

Resumo

“Osseointegration” as formulated by Alberktson is crucial for implant survival and success. Osseointegration is a measure of implant stability. Measuring implant stability helps to arrive at decisions as to loading of an implant, allows choice of protocol on a patient to patient basis and provides better case documentation. A successful implant reflects good bone to implant contact and is determined by implant stability both primary and secondary. Implant stability is achieved at two different stages – primary (immediately after implant placement) and secondary (3-4 months after implant placement). Implant stability has been confirmed to affect the process of osseointegration and therefore is essential to understand the methods to measure implant stability and factors influencing. Various methods are developed to assess implant stability which suggests the prognosis of an implant.

https://doi.org/10.36557/2674-8169.2020v2n12p45-59
PDF (English)

Referências

Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: Biological and biomechanical aspects and clinical implications. Periodontol 2000 2008;47:51-66.

Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998;11:491-501.

Shokri M, Daraeighadikolaei A. Measurement of primary and secondary stability of dental implants by resonance frequency analysis method in mandible. Int J Dent 2013;2013:506968.

Gupta RK, Padmanabhan TV. Resonance frequency analysis. Indian J Dent Res 2011;22:567-73.

Meredith N, Alleyne D, Cawley P. Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis. Clin Oral Implants Res 1996;7:261-7.

Atsumi M, Park SH, Wang HL. Methods used to assess implant stability: Current status. Int J Oral Maxillofac Implants 2007;22:743-54.

Sennerby L. Resonance frequency analysis for implant stability measurements. A review. Integr Diagn Update 2015;1:1-11.

Friberg B, Sennerby L, Gröndahl K, Bergström C, Bäck T, Lekholm U, et al. On cutting torque measurements during implant placement: A 3-year clinical prospective study. Clin Implant Dent Relat Res 1999;1:75-83.

Sullivan DY, Sherwood RL, Collins TA, Krogh PH. The reverse-torque test: A clinical report. Int J Oral Maxillofac Implants 1996;11:179-85.

Kaneko T. Pulsed oscillation technique for assessing the mechanical state of the dental implant-bone interface. Biomaterials 1991;12:555-60.

Kaneko T, Nagai Y, Ogino M, Futami T, Ichimura T. Acoustoelectric technique for assessing the mechanical state of the dental implant-bone interface. J Biomed Mater Res 1986;20:169-76.

Olivé J, Aparicio C. Periotest method as a measure of osseointegrated oral implant stability. Int J Oral Maxillofac Implants 1990;5:390-400.

Olsen S, Ferguson SJ, Sigrist C, Fritz WR, Nolte LP, Hallermann W, et al. A novel computational method for real-time preoperative assessment of primary dental implant stability. Clin Oral Implants Res 2005;16:53-9.

Lachmann S, Jäger B, Axmann D, Gomez-Roman G, Groten M, Weber H, et al. Resonance frequency analysis and damping capacity assessment. Part I: An in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability. Clin Oral Implants Res 2006;17:75-9.

Scarano A, Degidi M, Iezzi G, Petrone G, Piattelli A. Correlation between implant stability quotient and bone-implant contact: A retrospective histological and histomorphometrical study of seven titanium implants retrieved from humans. Clin Implant Dent Relat Res 2006;8:218-22.

Winter W, Möhrle S, Holst S, Karl M. Parameters of implant stability measurements based on resonance frequency and damping capacity: A comparative finite element analysis. Int J Oral Maxillofac Implants 2010;25:532-9.

Al-Jetaily S, Al-Dosari AA. Assessment of Osstell™ and Periotest ® systems in measuring dental implant stability (in vitro study). Saudi Dent J 2011;23:17-21.

Ahmad OK, Kelly JR. Assessment of the primary stability of dental implants in artificial bone using resonance frequency and percussion analyses. Int J Oral Maxillofac Implants 2013;28:89-95.

Feng SW, Chang WJ, Lin CT, Lee SY, Teng NC, Huang HM, et al. Modal damping factor detected with an impulse-forced vibration method provides additional information on osseointegration during dental implant healing. Int J Oral Maxillofac Implants 2015;30:1333-40.

Huang HM, Lee SY, Yeh CY, Lin CT. Resonance frequency assessment of dental implant stability with various bone qualities: A numerical approach. Clin Oral Implants Res 2002;13:65-74.

Valderrama P, Oates TW, Jones AA, Simpson J, Schoolfield JD, Cochran DL, et al. Evaluation of two different resonance frequency devices to detect implant stability: A clinical trial. J Periodontol 2007;78:262-72.

Atieh MA, Alsabeeha NH, Duncan WJ, de Silva RK, Cullinan MP, Schwass D, et al. Immediate single implant restorations in mandibular molar extraction sockets: A controlled clinical trial. Clin Oral Implants Res 2013;24:484-96.

Nedir R, Bischof M, Szmukler-Moncler S, Bernard JP, Samson J. Predicting osseointegration by means of implant primary stability. Clin Oral Implants Res 2004;15:520-8.

Atieh MA, Payne AG, Duncan WJ, Cullinan MP. Immediate restoration/loading of immediately placed single implants: Is it an effective bimodal approach? Clin Oral Implants Res 2009;20:645-59.

Snijders RS, van Wijk AJ, Lindeboom JA. A comparative study of the Osstell™ versus the Osstell Mentor™ to evaluate implant stability in human cadaver mandibles. J Oral Rehabil 2013;40:774-9.

Herrero-Climent M, Santos-García R, Jaramillo-Santos R, Romero-Ruiz MM, Fernández-Palacin A, Lázaro-Calvo P, et al. Assessment of Osstell ISQ's reliability for implant stability measurement: A cross-sectional clinical study. Med Oral Patol Oral Cir Bucal 2013;18:e877-82.

González-Jaranay M, Moreu-Burgos G, Gómez-Moreno G, Rubio-Roldán J, Machuca-Portillo G, Perrotti V, et al. Changes in resonance frequency analysis assessed by Osstell mentor during osseointegration: Comparison between immediately loaded implants and control implants without load. J Osseointegr 2014;6:51-5.

Jaramillo R, Santos R, Lázaro P, Romero M, Rios-Santos JV, Bullón P, et al. Comparative analysis of 2 resonance frequency measurement devices: Osstell mentor and osstell ISQ. Implant Dent 2014;23:351-6.

Krafft T, Graef F, Karl M. Osstell resonance frequency measurement values as a prognostic factor in implant dentistry. J Oral Implantol 2015;41:e133-7.

Creative Commons License
Este trabalho está licenciado sob uma licença Creative Commons Attribution 4.0 International License.

Copyright (c) 2020 Antonio Santos Araújo , Marcos Santos Araújo